Rebuilding instrument channel and archive data ============================================== We periodically need to recreate channel data and archive files due to gaps in the data caused by network communication drops, stopped drivers, server maintenance, etc. This is enabled using the ``manage-instruments`` script with a ``rebuilder`` command. This document outlines the workflow based on that command. Rebuild Sequence Diagram ------------------------ .. @startuml images/rebuild-workflow.png !include ../plantuml-styles.txt autonumber "" title "Rebuilding instrument channel data and archive files" actor Technician as tech participant "manage-instruments" as script participant TextRebuildApp as app participant "Disk Archive" as fs participant "Data Turbine" as dt tech o-> script: \t-c driver -o stop -i WK02XX_001CTDXXXXR00 note left Stop the driver and archiver for the instrument end note activate script script --> tech: \tok deactivate script tech o-> script: \t-c archiver -o stop -i WK02XX_001CTDXXXXR00 activate script script --> tech: \tok deactivate script tech -> script: \t-c rebuilder -o start -i WK02XX_001CTDXXXXR00 -f data.txt note left Rebuild the archive and channels end note activate script script --> tech: \tok script -> app: \tWK02.xml, data.txt deactivate script activate app app -> app: \tcreateConfiguration(WK02XX_001CTDXXXXR00.xml) app -> app: \tdata = loadData(data.txt) app -> app: \tdata = sort(data) app -> app: \tdata = dedupe(data) note left Load, sort, and dedupe the provided text file data end note app -> app: \tstart = getStartTime(data) note left Get the time range from the text data end note app -> app: \tend = getEndTime(data) app -> fs: \tfsdata = findData(start, end) deactivate app activate fs fs --> app: \tfsdata deactivate fs activate app app -> app: \tdata = appendData(fsdata) note left Append data from the disk archive for the time range end note app -> dt: \tdtdata = fetchData(start, end) deactivate app activate dt dt --> app: \t dtdata deactivate dt activate app app -> app: \tdata = appendData(dtdata) note left Append data from the data turbine for the time range end note app -> app: \tdata = sort(data) app -> app: \tdata = dedupe(data) note left Sort and dedupe all data end note deactivate app activate fs fs --> app: \tok deactivate fs activate app app -> fs: \tdeleteRawFiles(start, end) note left Delete and re-write raw disk archive files for the time range end note deactivate app activate fs fs --> app: \tok deactivate fs activate app app -> fs: \twriteRawFiles(start, end) deactivate app activate fs fs --> app: \tok deactivate fs activate app app -> dt: \tclearRawChannel(WK02XX_001CTDXXXXR00) note left Clear and re-write raw channel data for the time range end note deactivate app activate dt dt --> app: \tok deactivate dt activate app app -> dt: \twriteRawChannel(data) deactivate app activate dt dt --> app: \tok deactivate dt activate app app -> app: \tconverted = convert(data) note left Use the RawToPacIOOS2020Converter to convert data from raw to converted end note app -> fs: \tdeleteConvertedFiles(start, end) note left Delete and re-write converted disk archive files for the time range end note deactivate app activate fs fs --> app: \tok deactivate fs activate app app -> fs: \twriteConvertedFiles(converted) deactivate app activate fs fs --> app: \tok deactivate fs activate app app -> dt: \tclearConvertedChannel(WK02XX_001CTDXXXXR00) note left Clear and re-write converted channel data for the time range end note deactivate app activate dt dt --> app: \tok deactivate dt activate app app -> dt: \twriteConvertedChannel(converted) deactivate app activate dt dt --> app: \tok deactivate dt activate app app -->o tech: \tok deactivate app @enduml .. image:: images/rebuild-workflow.png The technician downloads data from an instrument flash card and saves it as a text file on ``realtime.pacioos.hawaii.edu``. They then use the ``manage-instruments`` script to stop the instrument driver and archiver so there's no activity for the Data Turbine channel and the disk archive directory for the given instrument. Once the realtime data and archiving is paused, the technician uses the ``manage-instruments`` script to rebuild the archive by providing the instrument identifier and the text file of the downloaded data. The script will spin up a ``TextRebuildApp`` that parses the instrument configuration file, loads the raw text data, sorts it based on the data timestamps, and deduplicates any repeat sample lines. Once complete, it gets the earliest and latest timestamps in the text file to establish the range of dates that need to be rebuilt in the disk archive and in the Data Turbine. It then finds the files in the disk raw archive directory within that time range, and appends the archived data to the already loaded raw data. Likewise, it fetches the raw data for the given time range from the Data Turbine and appends it as well. With all possible sources of raw data, the ``TextRebuildApp`` then sorts and and de-duplicates the data again, creating a rebuilt raw product. This is then written to the raw disk archive after deleting existing files in the time range. It then clears the Data Turbine raw channel, and repopulates that channel with the rebuilt data. After the raw files data are rebuilt, the ``TextRebuildApp`` uses the ``RawToPacIOOS2020Coverter`` to convert the data to the new format. It then deletes the converted disk archive files for the time range, and re-populates the converted Data Turbine channel for the instrument.